Installing The Non-Hot-Swap Power Supply - IBM System x3100 M4 Type 2582 Problem Determination And Service Manual

Type 2582
Hide thumbs Also See for System x3100 M4 Type 2582:
Table of Contents

Advertisement

10. If you are instructed to return the power supply, follow all packaging

Installing the non-hot-swap power supply

This procedure applies only to 4U server models with non-hot-swap power supplies.
Statement 8:
CAUTION:
Never Remove the server top cover on a power supply or any part that has
the following label attached.
Hazardous voltage, current, and energy levels are present inside any
component that has this label attached. There are no serviceable parts inside
these components. If you suspect a problem with one of these parts, contact
a service technician.
To install a non-hot-swap power supply on 4U server models with non-hot-swap
power supplies, complete the following steps.
1. Remove the air duct.
2. Remove the heat sink (see "Removing the microprocessor and heat sink" on
3. Position the power supply in the chassis so that the screw holes in the power
242
IBM System x3100 M4 Type 2582: Problem Determination and Service Guide
instructions, and use any packaging materials for shipping that are supplied to
you.
page 250).
supply are aligned with the corresponding holes in the rear of the chassis.

Hide quick links:

Advertisement

Table of Contents
loading