IBM x3100 M5 Type 5457 Installation And Service Manual page 425

Hide thumbs Also See for x3100 M5 Type 5457:
Table of Contents

Advertisement

806f0108-0a02ffff
[PowerSupplyElementName] has Failed. (Power Supply 2)
Explanation: This message is for the use case when an implementation has detected a Power Supply has failed.
May also be shown as 806f01080a02ffff or 0x806f01080a02ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0086
SNMP Trap ID: 4
Automatically notify Support: Yes
User response:
1.
Reseat power supply n.
2.
If the power-on LED is not lit and the power-supply error LED is lit, replace power supply n.
3.
If both the power-on LED and the power-supply error LED are not lit, see Power problems for more information.
(n = power supply number)
806f0109-1301ffff
[PowerSupplyElementName] has been Power Cycled. (Host Power)
Explanation: This message is for the use case when an implementation has detected a Power Unit that has been
power cycled.
May also be shown as 806f01091301ffff or 0x806f01091301ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0108
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f010c-2001ffff
Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 1)
Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error.
May also be shown as 806f010c2001ffff or 0x806f010c2001ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0138
SNMP Trap ID: 41
Automatically notify Support: Yes
User response:
1.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
2.
Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different
memory channel or microprocessor.
3.
If the problem follows the DIMM, replace the failing DIMM.
806f0108-0a02ffff • 806f010c-2001ffff
Appendix A. Integrated management module II (IMM2) error messages
409

Advertisement

Table of Contents
loading

Table of Contents