2.2 Connection between GOT and Controllers

2.2.1

Connection type used for the MES Interface Function

The following table shows the GOT supporting the MES interface function and availability in each connection type.
For system configuration when using the MES interface function, refer to the following manual:
GOT1000 Series Connection Manual for GT Works3 and a controller used
*4
Mitsubishi PLC connection
Inverter connection
Servo amplifier connection
*5
Robot controller connection
*6
CNC connection
Third party PLC connection
Third party safety controller connection
Third party servo amplifier connection
Third party robot controller connection
Third party temperature controller connection
Microcomputer connection
MODBUS
/RTU connection
MODBUS
/TCP connection
*1
For the MELSECNET/10 connection, use the MELSECNET/H communication unit.
The MELSECNET/10 communication unit cannot be used.
*2
For the CC-Link connection, use the CC-Link communication unit (GT15-J61BT13).
The CC-Link communication unit (GT15-75J61BR13-Z) cannot be used.
*3
For the inverter or servo amplifier connection, use the status observation function or the script function to assign devices.
For how to assign devices, refer to the following:
2.2.2 Precautions for inverter or servo amplifier connection
*4
Including connection to the motion controller CPU (Q series and A series), CNC C70, and CRnQ-700
*5
Applicable to the CRnD-700 only. For the CRnQ-700, refer to the above Mitsubishi PLC connection.
*6
Applicable to the MELDAS C6/C64 only. For the CNC C70, refer to the above Mitsubishi PLC connection.
*7
For connecting GT16 to a device supporting 10BASE(-T/2/5), configure the network that supports both 10Mbps and 100Mbps
communication speeds by using a switching hub.
*8
The GT1665HS-V cannot be used.
Connection type
Bus connection
Direct CPU connection
Computer link connection
*7
Ethernet connection
MELSECNET/H connection (PLC to PLC network)
MELSECNET/10 connection (PLC to PLC network)
CC-Link IE controller network connection
CC-Link IE field network connection
CC-Link connection (Intelligent device station)
CC-Link connection (via G4)
Serial connection
*7
Ethernet connection
MELSECNET/10 connection (PLC to PLC network)
CC-Link connection (Intelligent device station)
Serial connection
*7
Ethernet connection
Serial connection
*7
Ethernet connection
2.2 Connection between GOT and Controllers
: Applicable
: Partly restricted
: Not applicable
*8
GT16
/GT15
*1
*2
*3
*3
*1
*2
1
2
3
4
5
6
7
8
2 - 3