Mitsubishi Electric GOT 1000 Series Manual page 102

Graphic operation terminal
Hide thumbs Also See for GOT 1000 Series:
Table of Contents

Advertisement

(1) Combination
(a) Selects a combination of [Trigger 1] and [Trigger 2].
• OR (When either of them is true, the result is true.)
• AND (When both of them are true, the result is true.)
When the combination result of [Trigger 1] and [Trigger 2] is changed from false to true, the job is activated.
(b) The following shows the timings at which the combination result of [Trigger 1] and [Trigger 2] is changed
from false to true.
(In any other cases, because the combination result is not changed from false to true, the job is not
activated.)
OR (When either of them is true, the
result is true.)
AND (When both of them are true,
the result is true.)
6 - 26
6.7 Job Settings
Combination
(Changed from false to true)
False
(Changed from false to true)
False
(Remained false)
True
False
(Changed from false to true)
False
(Changed from false to true)
False
(Remained true)
True
False
Trigger 1
(Remained false)
True
True
False
(Changed from false to true)
True
False
(Changed from false to true)
False
(Remained true)
True
True
False
(Changed from false to true)
True
False
(Changed from false to true)
False
Trigger 2
Combination result
True
True
(Changed from false to true)
False
True
True
True