(7) Exception processing setting
A click on the
(Example) When [Select] is selected for [Action type]
(a) Exception processing: No applicable record
When [Select], [Update] or [MultiSelect] is selected for [Action type], set processing for the case where
there is no record to be selected, updated or multi-selected.
1) Send notification of this exception
When the [Send notification of this exception] box is checked, if there is no record to be selected,
updated or multi-selected, assign a value to the specified tag component.
When [Send notification of this exception] is selected, set a tag component to which the value is
assigned.
• Tag, Component
Select a tag component to which a value is assigned.
Tags that have a tag component with [Array setting] cannot be selected.
• Substitute value
Directly enter a substitute value.
2) Continue this job
After execution of exception processing described in the above 1), the system continues executions of
other actions.
3) Finish this job (Default: Finish this job)
After execution of exception processing described in the above 1), the job is forcibly terminated without
executing remaining actions.
At this time, substitute/insert values before exception processing execution are committed, and they are
written to relevant tag components.
6 - 56
6.8 Job Settings - Actions
Exception process setting
button displays the [Exception process setting] dialog box.