Mitsubishi Electric GOT 1000 Series Manual page 215

Graphic operation terminal
Hide thumbs Also See for GOT 1000 Series:
Table of Contents

Advertisement

Error code
(ProgramExec: [IP address]: <...>: Failed)
0x20700020
Failed to log on in remote execution.
(ProgramExec: [IP address]: <...>: Failed)
0x20700021
Failed to load user profile during remote execution.
(ProgramExec: [IP address]: <...>: Failed)
0x20700023
Failed to generate process during remote execution.
(ProgramExec: [IP address]: <...>: Failed)
0x20700024
Timeout or aborted of waiting to complete remote
execution.
(SID [Session ID]: TCPOpen Request Error: [IP address])
0x20800010
Invalid TCPOpen request
Error description and cause
Corrective action
• In [MES interface setting], set correct user name and
password for the application server setting.
6.6 Server Service Settings
• Check if the user account is invalid or not by
Administrative Tools of Windows
.
• Check if the setting is forcing the user to enter
password at next logon by Administrative Tools of
Windows
.
• Check if the user password is expired or not by
Administrative Tools of Windows
.
• No user profile for Windows
has been created.
• Confirm that the user ID set for the application server
setting of the MES interface setting can be used to log
on Windows
, and reexecute.
• Check if the application to be executed in remote
execution exists or not.
• Check if the name of the application to be executed in
remote execution is a directory.
• Make a proper security setting for the application to be
executed in remote execution.
• Set the longer time to the DB access timeout for DB
Connection Service Setting Tool.
• Exit the application for the remote execution before
logging off.
• Check the source IP address setting.
• Confirm the version of the option OS (MES Interface).
8.2 Error Code List
1
2
3
4
5
6
7
8
8 - 17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents