8.2.2

DB Connection Service

The DB Connection Service outputs errors to the Windows
For Windows Vista
(1) Event log of Windows
(a) Event log output warning list of DB Connection Service (Source name: DBConnector)
Warning event ID
1
(b) Event log output warning list of DB Connection Service (Source name: DBConnector)
Error event ID
1
2
5
6
9
101
102
103
104
105
8 - 10
8.2 Error Code List
, DB Connection Service Client also outputs errors to Windows
Error description and cause
There is no setting file.
Start the service using the default setting.
Error description and cause
Unable to start the service due to insufficient memory.
Unable to start the service due to insufficient resources.
Failed to read the setting file.
The service is stopped.
Failed to initialize the log file.
The service is stopped.
The server port has already been opened.
The service is stopped.
The computer ran out of memory while reading the setting
file.
The setting file path is too long.
The setting file name indicates the directory.
The setting file could not be opened.
Description of the setting file is not correct.
Event Log, access log, and SQL failure log.
• Configure the settings again with DB Connection
Service Setting Tool.
7.5 Setting Items of DB Connection Service
Setting Tool
• Add more memory to the personal computer.
• Refer to the actions of error codes 101 to 129.
• Actions are displayed with error codes 101 to 129.
• Refer to the actions of error codes 401 to 403, and 501
to 503.
• Actions are displayed with error codes 401 to 403, and
501 to 503.
• Change the server port No. with DB Connection
Service Setting Tool.
7.5 Setting Items of DB Connection Service
Setting Tool
• Terminate any unnecessary applications.
• Add more memory to the personal computer.
• Reinstall the DB Connection Service to the directory
whose path name is shorter.
• Reinstall the DB Connection Service.
• Terminate other applications, and make the setting
again with DB Connection Service Setting Tool.
7.5 Setting Items of DB Connection Service
Setting Tool
Event Log.
Corrective action
Corrective action
(To the next page)