Error code
(SID [Session ID]: Response Transmit Error: [IP address])
0x20310010
Failed to transmit a response due to disconnection.
(SID [Session ID]: Response Transmit Error: [IP address])
0x20310011
Timed out during response transmission.
(SID [Session ID]: Response Transmit Error: [IP address])
0x20310012
Detected failure of the MES interface module during
response transmission.
(SID [Session ID]: Response Transmit Error: [IP address])
0x20310013
Send I/O error
(SID [Session ID]: DB Connect: [Data source]: [User]:
0x20400001
Failed)
Failed in DB connection due to insufficient memory.
(SID [Session ID]: DB Connect: [Data source]: [User]:
0x20400002
Failed)
Failed in DB connection due to insufficient resources.
(SID [Session ID]: DB Connect: [Data source]: [User]:
0x20400010
Failed)
Invalid DB connection request
(SID [Session ID]: DB Connect: [Data source]: [User]:
0x20400020
Failed)
Failed to create a DB handle.
(SID [Session ID]: DB Connect: [Data source]: [User]:
0x20400022
Failed)
Failed in DB connection.
(SID [Session ID]: SQL<...>: Failed)
(SID [Session ID]: COMMIT: Failed)
(SID [Session ID]: ROLLBACK: Failed)
0x20600001
(SID [Session ID]: GetNext: Failed)
(SID [Session ID]: Reset: Failed)
Failed in SQL execution due to insufficient memory.
(SID [Session ID]: SQL<...>: Failed)
(SID [Session ID]: COMMIT: Failed)
(SID [Session ID]: ROLLBACK: Failed)
0x20600002
(SID [Session ID]: GetNext: Failed)
(SID [Session ID]: Reset: Failed)
Failed in SQL execution due to insufficient resources.
Error description and cause
Corrective action
• Check if it is connected to the network.
• Check if the gateway and/or hub is operating.
• Check if the power of the GOT has not been turned off.
• Terminate any unnecessary applications.
• Add more memory to the personal computer.
• Check the source IP address setting.
• Confirm the version of the option OS (MES Interface).
• Terminate any unnecessary applications.
• Add more memory to the personal computer.
• Set correct data source name, user name, and
password in [Server service settings] of [MES interface
setting].
6.6 Server Service Settings
• Check if the personal computer is restarted after the
database is installed. Restart the personal computer if
not restarted.
• Terminate any unnecessary applications.
• Add more memory to the personal computer.