6.6.1

Setting items in Server service settings

Up to 8 items can be set in [Server service settings] within one project.
Item
Sever service name
Server type
IP address
Port No.
User name
Password/Confirm password
Data source name
Database type
Access error notification setting
Connection timeout
6 - 18
6.6 Server Service Settings
Enter a server service name. (Up to 16 characters)
Select the server type of the server computer to be accessed.
Enter a decimal IP address of the server computer where DB Connection Service is installed.
Set a port number of the server computer.
(Range: 1024 to 65535, Default: 5112)
Set a user name used to access the server computer.
(Up to 30 characters)
Set a password used to access the server computer.
(Up to 30 characters)
Set the name of the ODBC data source to be accessed.
Select the type of the database server.
Set whether to enable or disable notification of the access error status.
In case a connection error occurs on the network between the GOT and the server computer, set a timeout
time during which the GOT will detect the error.
(Range: 1 to 180 seconds, Default: 10 seconds)