(1) Job name (Up to 16 characters)
Enter a job name.
For characters that can be used for job names, refer to the following:
Appendix.1.2 Characters applicable to item names, component names, variable names, etc.
(2) GOT Initializing
(a) Set whether to enable the job at startup of the GOT or not.
If the [GOT Initializing] box is not checked, the job is disabled at startup of the GOT. (Even if trigger
conditions are met, the job is not executed.)
(b) When the GOT is ON, the enable/disable setting of the job can be changed in [Change Job Status] on the
[Diagnosis] tab.
6.10.3 Changing the job status (Change job status)
(3) Trigger buffering
(a) Set whether to enable the trigger buffering function or not.
For the trigger buffering function, refer to the following:
5.1.5 Trigger buffering function
(b) Precautions for enabling [Trigger buffering]
• [Handshake operation] cannot be selected for the trigger conditions.
• A tag component cannot be selected for the substitution tag in [Operation action].
• Tag component values cannot be set for [DB-tag link setting] in [Select] of [Communication action].
• [Communication action] - [MultiSelect] cannot be selected.
• Up to 4096 words can be used for the total data length of tag components in one job. (The current data
length is displayed on the status bar of [Job setting].)
POINT
POINT
POINT
The total data length of tag components in one job is the total data length of tag components set in [Communication
action] and [Operation action]. In [Communication action], tag components are set in [Select/Update conditions]
and [DB-tag link setting].
All tags in one job are treated as different tags even if there are the same tags.
(4) Startup logging
(a) Set whether to output the startup history of the job to the log or not.
If this function is enabled, the job startup timing can be checked during system start-up or tune-up.
When the [Startup logging] box is checked, the startup history of the job (date and time, job name, trigger
conditions) is saved on a CF card.
The startup log can be confirmed in [Job Execute Log] on the [Working log] tab.
6.11.2 Job Execute Log
(b) When the log capacity becomes full (Log capacity: 1MB
The first half of the data are deleted.
The latest log is stored after the remaining data.
(c) When this function is enabled, a processing time is required for saving or deleting the startup history of the
job.
It is recommended to disable this function during system operation.
2)
6.7 Job Settings
1
2
3
4
5
6
7
8
6 - 23