Technical data

1.4
Technical data
Electrical data (standard and redundant power supply)
Rated voltage range
Frequency
Rated current with basic configuration
Max. rated current
Effective power
Apparent power
Heat dissipation
Main power fuse
Protection class
Compliance with regulations and standards
Product safety and
ergonomics
Electromagnetic
Compatibility
Interference emissions EN 55022 class A
Harmonic current
Flicker
Interference immunity EN 55024
CE marking
under EU directives
14
IEC 60950 / EN 60950 / UL 60950 3rd.Ed.,
CAN/CSA-C22.2 No.60950 3rd.Ed.
FCC class A
VCCI class A
AS/NZS 3548 class A
CNS 13438
EN 6100-3-2 JEIDA
EN 61000-3-3
Low-Voltage Directive 73/23/EEC Electromagnetic
Compatibility
89/336/EEC (Product safety)
Operating Manual
100 V - 240 V
50 Hz - 60 Hz
100 V - 240 V / 1.9 A - 0.8 A
100 V - 240 V / 6 A - 3 A
270 W
276 VA
972 kJ/h (921 btu/h)
16 A
I