Fujitsu ETERNUS CS800 User Manual page 68

Hide thumbs Also See for ETERNUS CS800:
Table of Contents

Advertisement

3.2   Storage Modules
LED name
IDENTIFY/SCU
READY
DI (OUT)LINK/
FAULT
READY/FAULT
MASTER
CA FAULT
LINK/FAULT
LAN ACCESS
LAN LINK
Figure 38: Status and Meanings of Each LED (Controller)
68
LED status
Description
blinks green
green
The link between the DI (OUT) port and the
destination port has been established.
amber
blinks amber
The ports to connect the cables are indicated.
This occurs while a drive enclosure is being
added.
green
The link between the DI (OUT) port and the
destination port has been established.
blinks green
An error has occurred during startup.
amber
The controller is performing the initial setup after
the power is turned on.
blinks amber
The controller is in error status.
green
The controller is set as a Master CM.
amber
The host interface is in error status.
green
The link between the host interface port and the
destination port has been established.
amber
The host interface port is in error status.
blinks green
Data is being sent or received via the LAN port
(for operation management).
green
The link between the LAN port (for operation
management) and the destination has been
established.
Specifies the installation location of the
l
controller module.
System Capacitor Unit (SCU) is charging.
l
The link between the DI (OUT) port and the
l
destination port is in error status.
The ports to remove the mini SAS HD
l
cables between enclosures from are
indicated. This occurs while a drive
enclosure is being added.
ETERNUS CS800

Advertisement

Table of Contents
loading

Table of Contents