Using the Network page, each physical Ethernet port in the ETERNUS CS800 can be
configured as a separate device. In addition, you can create bonded devices (logical ports)
consisting of two or more physical ports of the same link speed (1GbE or 10GbE). For each
port or device, you can specify the MTU (Maximum Transmission Unit) frame size.
After you define devices (single port or bonded), you can create up to ten network interfaces
for each device. Each interface has its own IP address information. In addition, you can
configure the following options for each interface:
Assign the interface to a VLAN (Virtual Local Area Network).
l
Indicate whether the interface IP address will be used to externally identify the system
l
(external host IP address).
Specify the types of traffic allowed on the interface (management, replication, or data).
l
Specify the NAT address that the interface is mapped to if it is used for replication
l
through a NAT firewall.
Add routing information for an interface to enable connectivity with devices on different
l
subnets.
You can choose to allow any traffic type (management, replication, or data) on an
interface. In this case, the routing of different traffic types, as well as firewall
capability, must be controlled using the network infrastructure (routers and
switches) that the ETERNUS CS800 is connected to.
The iRMC port of the server cannot be configured through the Web GUI of the
ETERNUS CS800. Using the iRMC port is typically not necessary. For example
the hardware monitoring of the iRMC is also included by the monitoring of the
CS800 itself. If you nevertheless want to connect the iRMC to your network, you
have to change its network settings either through the servers' BIOS (see
PRIMERGY RX2540 M1 Server D3289 BIOS Setup
ServerView iRMC Web Server as described in the
Management Controller
The default settings of the iRMC Web Server are:
l
l
The service port of the ETERNUS CS800 cannot be configured and should not be
connected to the LAN.
Configuring the network includes the following major steps:
ETERNUS CS800
manual).
IP address: 10.17.21.199 with network mask 255.255.255.0 and gateway IP
10.17.21.254
login: admin with password admin
6   Initial Configuration, Connecting with the Network
Utility) or through the
iRMC S4 - integrated Remote
115