Fujitsu ETERNUS CS800 User Manual page 66

Hide thumbs Also See for ETERNUS CS800:
Table of Contents

Advertisement

3.2   Storage Modules
Figure 35: Operation Panel (Controller Enclosure)
LED name
POWER
IDENTIFY
FAULT
MAINTENANCE green
CACHE
READY
Table 12: Status and Meanings of Each LED (Operation Panel - Base Module)
For detailed information on ETERNUS DX100 S3 storage module see
storage module manuals.
66
LED status
Description
green
DC power is supplied to the controller enclosure.
blue blinking
The installation location of the controller enclosure is
identified according to the instruction that is issued
from ETERNUS Web GUI or ETERNUS CLI.
amber
The system is in error status.
blinks amber
A part of the ETERNUS DX requires preventive
maintenance.
Maintenance for the ETERNUS DX is in progress.
blinks green
Maintenance or a status check via ETERNUS Web
GUI or ETERNUS CLI is necessary.
green
There is data in the cache memory of the ETERNUS
DX.
green
The ETERNUS DX is available for use..