pbxLink connection

Contents

This section contains the following topics:

Introduction

pbxLink Connection Failure Detection and status reporting provide the
following functionality:

pbxLink connection failure detection

The Call Server, which maintains a list of all known registered elements
(Signaling Servers and Voice Gateway Media Cards), monitors the pbxLink.
When booted, a Call Server has a 5-minute delay to enable these known
elements to reestablish contact with the Call Server.
If a known element fails to register with the Call Server, an ELAN0028
alarm is generated.
If an unknown Signaling Server or Voice Gateway Media Card registers with
the Call Server, an ELAN0029 alarm is generated.
Copyright © 2007, Nortel Networks
.
"Introduction" (page 183)
"pbxLink connection failure detection" (page 183)
"LD 117 STAT SERV enhancement" (page 185)
The pbxLink Connection Failure Detection feature provides a way to
detect the link status of Signaling Servers and Voice Gateway Media
Cards. An alarm is generated if the pbxLink is not detected after a warm
or cold start of the Call Server.
The STAT SERV command in LD 117 displays the link status of the
Signaling Server and Voice Gateway Media Cards that are configured
to connect to the system. The display also provides information about
the applications that run on the Signaling Server and Voice Gateway
Media Cards.
Nortel Communication Server 1000
Communication Server 1000E Maintenance
NN43041-700 01.02 Standard
Release 5.0 20 June 2007
183