104 Database management
Equipment requirements
CCBR requires the following equipment:
To remotely access the system, connect a modem to an SDI port on the
SSC card or on the CP PM card.
To locally access the system, connect a computer directly to an SDI port on
the SSC card or on the CP PM card.
Feature operations
Procedure 9
Backing up the customer configuration database
Step
1
2
3
4
5
Copyright © 2007, Nortel Networks
.
a computer that supports Xmodem communications protocol
Ensure that your communications package complies with the protocol
specifications described in Communication Server 1000E Installation
and Commissioning (NN43041-310). Not all Xmodem protocols are
identical. Some may not operate properly with the CCBR feature.
modems for remote access
Action
Log on to the system.
Perform a data dump using LD 43, as shown in
Dump" (page
102).
Type **** to exit LD 43.
Type LD 143.
The system responds with the following:
CCBR000
.
Review Steps 5 through 7 before you proceed. If you do not perform
these steps within approximately 5 minutes after you issue the XBK
command, the system times out.
Type XBK.