124 Replacing equipment

Replacing the NT4N64 CP PII Call Processor card

Procedure 19
Replacing the NT4N64 CP PII Call Processor card
Step
1
2
3
4
5
6
7
Copyright © 2007, Nortel Networks
.
The red LED remains lit until the card is configured and enabled.
When the card has finished booting, the faceplate display shows
Fxxx or Lxxx (where xxx is the number of telephones registered to
the card), indicating that the card is a Follower or Leader.
Action
Check the System Utility card maintenance display to verify that the
Call Server containing the CP PII card to be replaced is inactive.
a. If the Call Server containing the CP PII card is active, switch
Call Servers in LD 135:
LD 135
SCPU
In LD 135, split the CPU cores:
SPLIT
Remove all cables connected to the CPU being replaced.
Use a small-bladed screwdriver to remove the screws from the CP
PII card.
To remove the card, hold the card by the faceplate latches and gently
pull it out of the slot.
To install the replacement card, hold the card by the faceplate
latches and gently push it into the slot until the connectors make
contact with the backplane.
Gently push the latches forward to set the card and lock it in place.
CAUTION
Damage to Equipment
Never force the card into the slot. It the card gets stuck,
remove it and try again.
Nortel Communication Server 1000
Communication Server 1000E Maintenance
NN43041-700 01.02 Standard
Release 5.0 20 June 2007
—End—
To load the program.
Switch Call Servers (if necessary).