3
4
5
6
Using the STAD command
Effective in CS 1000, Release 5.0, only users that have SEC_ADMIN
privileges can change the system time and date. For more information about
Release 5.0 security enhancements, see Security Management Fundamentals
(NN43001-604).
7
8
9
Copyright © 2007, Nortel Networks
.
Ensure the system utility card has the correct DIP switch settings for
CPU 0 or CPU 1 as required. Also ensure that the enable/disable
switch is configured to enable.
Make sure all wiring and connectors that could have been
disconnected are reconnected.
Configure the midnight routine to run after logging out of the system
by entering:
LD 135
MIDN
End the session in LD 135 and log out of the system by entering:
**** (four asterisks)
LOGO
The midnight routine runs now.
Check system messages produced when the midnight routine runs.
Clear any faults indicated.
If a sysload occurred while clearing a fault, reset the correct time
and date by entering:
LD 2
STAD (day) (month) (year) (hour) (minute) (second)
Check the time and date entered:
TTAD
End the session in LD 2 and log out of the system:
**** (four asterisks)
LOGO
Replace any covers that were removed.
Tag defective equipment with a description of the fault and return it
to a repair center.
Nortel Communication Server 1000
Communication Server 1000E Maintenance
NN43041-700 01.02 Standard
Release 5.0 20 June 2007
Fault clearing process 71
ATTENTION
—End—