98 Clearing faults
If the fault does not clear, manual continuity tests can be used to isolate
faults to peripheral equipment, such as E&M or Universal Trunk circuit cards.
See Software Input/Output Reference – Maintenance (NN43001-711) for
details on performing the tests in LD 30.
Trunk connections from the main frame to the trunk cards can be checked
with a butt telephone or test telephone. Check the trunk wiring at the entry
point for dial tone and progress toward the Media Gateway.
Constantly observe and look up system messages as you replace
equipment.
You may need to replace:
Table 35 "Trunk cannot make or receive calls(OVD message may be
received)" (page 98)
in an MG 1000E or MG 1000T
Table 35
Trunk cannot make or receive calls
(OVD message may be received)
Possible cause
Excessive traffic in
the system
Defective trunk circuit
card
Copyright © 2007, Nortel Networks
.
E&M Trunk circuit card: NT8D15
Universal Trunk circuit card: NT8D14
any other trunk circuit card
NTDK20 SSC card
NTAK03 TDS/DTR circuit card
trunk equipment (such as music source or paging equipment)
provides additional instructions for isolating trunk faults
Action
Additional trunk circuit cards may be required to handle the traffic in the
system.
If the indicated circuit card is an E&M or Universal Trunk circuit card,
hardware-disable it and then reenable to initiate a self-test.
If the test fails, replace the circuit card. If the test passes, disconnect the
wiring between the circuit card and the cross-connect terminal.