Type XRT to begin the configuration database restore.
The system prepares to receive the database file from the computer
and restore it to the SSC (CP PII and CP PIV) or to the Call Server
(CP PM).
The system responds with the following:
WAIT - - 2 MINUTES
R>
WARNING
The receiving file is erased at the start of this step. If a
problem occurs during the restore procedure, do not leave
the system in this state. Repeat the restore procedure. If
you encounter further problems, perform an EDD to dump
the current data to the SSC (CP PII and CP PIV) or to
the Call Server file (CP PM).
Send the backed up database file to the system using the
communications software and the XModem protocol on the
computer.
The system displays the character C every 3 seconds until the
file transfer is complete. The file transfer must finish before the
character C appears 20 times (approximately 1 minute) to avoid
a system timeout.
The system site ID, n the configuration database records being sent,
is compared to the ID on the system. If the IDs do not match, the
data is restored, but the following warning message appears:
BKP0011
When the database restore succeeds, the system responds: OK.
Nortel Communication Server 1000
Communication Server 1000E Maintenance
NN43041-700 01.02 Standard
Release 5.0 20 June 2007
Customer Configuration Backup and Restore 107
The site ID in the restored data does not match that
of the system. This response is normal when you
use this procedure as part of an installation process.
Corrective action:
Ensure that the customer data file is correct and that
you are not restoring the wrong file to the system. If
the file is correct, contact Nortel technical support.