Interactive Diagnostics - Nortel 1000E Maintenance Manual

Nortel communication server maintenance manual
Hide thumbs Also See for 1000E:
Table of Contents

Advertisement

The Events Monitor window displays active events in a way that you can
quickly view the most important events. System events with a severity of
critical, major, or minor are considered alarms. These alarms are events
that can require corrective action. System events with a severity of Info are
for informational purposes only and are not considered alarms.
Alarm Notification
The Alarm Notification application receives SNMP events from designated
network equipment over an Ethernet network and sends out alarm
notifications when specified event conditions are detected. Received events
are compared to a set of rules that can activate notifications of different
types. These notifications include:
For detailed information about Alarm Management, see Telephony Manager
3.1 Telemanagement Applications Fundamentals (NN43050-602) and
Communication Server 1000 Fault Management – SNMP (NN43001-719).

Interactive diagnostics

Load nonresident software programs into the memory through the TM
System Terminal or an SDI terminal. These programs, also called overlays
or loads, are identified by a title and a number that is preceded by the
mnemonic for load (for example, Trunk Diagnostic — LD 36).
The programs used in Midnight and Background Routines are also used
manually as interactive diagnostic programs. See
in Midnight and Background Routines" (page
Nonresident programs are used interactively with a command and response
format. In this format, enter a command that tells the system to perform a
specific task. The system performs the task and sends system messages
indicating status or errors back to you.
With interactive diagnostics you can:
Copyright © 2007, Nortel Networks
.
SNMP traps or events transmitted to predefined destinations
text notification over a modem
pager notification to alpha or numeric pagers
e-mail using Simple Mail Transfer Protocol (SMTP)
log
Disable, test, and enable specific equipment.
Verify that a reported fault still needs to be cleared.
Verify that a repair procedure has cleared a fault.
Nortel Communication Server 1000
Communication Server 1000E Maintenance
NN43041-700 01.02 Standard
Release 5.0 20 June 2007
Interactive diagnostics 67
Table 16 "Programs used
62).