Procedure 14
Backing up the NRS database
Step
1
2
3
4
5
6
Replace a CP PM Signaling Server card
After you create a bootable RMD with software and you complete the NRS
backup, you can replace the CP PM Signaling Server card. For more
information, see
(page
Copyright © 2007, Nortel Networks
.
Replacing NTDW61 CP PM Signaling Server equipment 115
Action
Log on to the system.
Insert a CF card into the RMD slot to back up the database.
To load the Equipment Data Dump Program (LD 43), at the prompt
enter:
Load program
LD 43
EDD
.
After "EDD000" appears on the terminal, enter:
Begin the data dump.
EDD
CAUTION
Service Interruption
Loss of Data
If the data dump is not successful, do not continue;
contact your technical support organization. A data dump
problem must be corrected before you proceed.
After "DATADUMP COMPLETE" and "DATABASE BACKUP
COMPLETE" appear on the terminal, enter:
Exit program
****
Remove and label the CF card.
Procedure 15 "Replacing a CP PM Signaling Server card"
116).
Nortel Communication Server 1000
Communication Server 1000E Maintenance
NN43041-700 01.02 Standard
Release 5.0 20 June 2007
—End—