CP PM Call Processor faceplate LEDs
The status LED indications of the NTDW61 CP PM Call Server are as
follows:
The Active CPU LED indications are as follows:
The ELAN LED indications are as follows:
The HSP LED indications are as follows:
Copyright © 2007, Nortel Networks
.
CAUTION
SERVICE INTERRUPTION
During a sysload, active calls are disconnected and the system
goes into an emergency line transfer state. Use the reset button
only when specifically instructed to do so in an NTP.
Off: no power
Red: BIOS self-test running
Flashing red: bootrom and Operating System (OS) loading
Yellow: sysload phase 1
Flashing yellow: sysload phase 2
Flashing green: SL1 loading on active core
Green: normal operation
Off: no power
Green: redundant mode, active
Flashing green: split mode, active
Yellow: redundant mode, standby
Flashing yellow: split mode, standby
Red: single mode
LED1 Off: 10 Mbps
LED1 Yellow: 100 Mbps
LED2 Off: no link, no activity
LED2 Green: link valid
LED2 Blink: link valid and activity
LED1 Off: 10 Mbps
LED1 Yellow: 100 Mbps
LED1 Green: 1000 Mbps
Nortel Communication Server 1000