Replacing IP daughterboards

Procedure 42
Replacing the NTDK83 or NTDK99 IP daughterboard
Step
1
2
3
4
5
6
7
8
9
10
11
12
13
Copyright © 2007, Nortel Networks
.
Reboot system by setting the power supply off, and then on.
Action
Turn the power supply and reserve power off.
Unplug the IP cable from the Media Gateway bulkhead.
Unplug and remove the NTDK20 SSC from the Media Gateway and
place on a clean flat surface.
Disconnect the cable from the IP daughterboard and the LED
connector if used.
Detach the IP daughterboard.
Position the replacement IP daughterboard.
Seat the replacement IP daughterboard into the same slot you
removed the defective IP daughterboard from on the NTDK20 SSC
card.
Reconnect the IP cable. Ensure that the cable is fully inserted
into the connector. A click should be heard when the cable is fully
engaged.
Reconnect the LED connector that was disconnected in
necessary.
Record the MAC address of the new IP daughterboard installed
on the SSC in the Media Gateway. When necessary use LD 117
to configure the new MAC address for the Media Gateway. See
Communication Server 1000E Installation and Commissioning
(NN43041-310).
Reinstall the NTDK20 SSC circuit card in slot 0 of the Media
Gateway.
Reconnect the IP cable to the Media Gateway bulkhead.
Power up the system.
Nortel Communication Server 1000
Communication Server 1000E Maintenance
NN43041-700 01.02 Standard
Release 5.0 20 June 2007
Replacing IP daughterboards 149
—End—