82 Clearing faults
4
5
MG 1000E faults
The MG 1000E provides the interface between network switching and
terminal equipment (such as trunks and telephones). MG 1000E faults can
disable network and terminal equipment. See
indicators" (page 83)
An overload (OVD) message on an MG 1000E indicates a network loop is
disabled and that all connections on the loop are disabled. The network
loop number corresponds to a specific card number in the MG 1000E.
System messages can also indicate that one or more cards is defective or
disabled without producing an OVD message. In either case, look up all
system messages in Software Input/Output Reference – System Messages
(NN43001-712) and follow the instructions given.
Manual continuity tests can also be used to isolate Network and Intelligent
Peripheral Equipment (IPE) faults. See Software Input/Output Reference –
Maintenance (NN43001-711) for details on performing the tests.
If the fault does not clear, or when call processing has stopped on the MG
1000E, you may need to replace the following equipment:
Copyright © 2007, Nortel Networks
.
Use the PING <ip address of the MG 1000E> command in
LD 117 to verify network connection.
Reenable any disabled components. Verify the 100BaseT
connection between the Call Server and the MG 1000E is operating
by pinging the IP address of the MG 1000E(s) configured.
The MG 1000E supports only Layer 2 and Layer 3 switches.
Software-based routers are not recommended.
for MG 1000E fault indicators.
Media Gateway Controller card (NTDW60)
Media Gateway Controller daughterboards (NTDW62 and NTDW64)
NTDK20 SSC card
— NTTK25 software daughterboard
— NTDK83 100BaseT dual-port IP daughterboard
— NTDK99 100BaseT single-port IP daughterboard
NTDU0606 CAT5 Ethernet cable used to connect the NTDK99 IP
daughterboard to the bulkhead connectors
CAT 5 IP cables
Nortel Communication Server 1000
Communication Server 1000E Maintenance
NN43041-700 01.02 Standard
Release 5.0 20 June 2007
ATTENTION
—End—
Table 25 "MG 1000E fault

Advertisement