Network Monitoring
●
Basic system management........................................................................................... 229
●
RMON support.............................................................................................................. 240
●
sFlow.............................................................................................................................245
●
Utilization list for an uplink port..................................................................................... 263
Basic system management
The following sections contain procedures for basic system management tasks.
Viewing system information
You can access software and hardware specifics for a Brocade Layer 2 switch or Layer 3 switch. For
software specifics, refer to the section
in the FastIron Ethernet Switch Administration Guide.
To view the software and hardware details for the system, enter the show version command. The
following shows example output.
NOTE
The output may vary depending on the device on which you run the show version.
device# show version
==========================================================================
Active Management CPU [Slot-9]:
SW: Version 04.3.00b17T3e3 Copyright (c) 1996-2008 Brocade Communications, Inc.,
Inc.
HW: ANR-Chassis FastIron SX 1600-PREM (PROM-TYPE SX-FIL3U)
==========================================================================
SL 3: SX-FI424C 24-port Gig Copper
==========================================================================
SL 9: SX-FI8GMR4 8-port Management
==========================================================================
SL 14: SX-FI42XGW 2-port 10G LAN/WAN
==========================================================================
Active Management Module:
660 MHz Power PC processor 8541 (version 32/0020) 66 MHz bus
512 KB boot flash memory
16384 KB code flash memory
512 MB DRAM
The system uptime is 2 minutes 13 seconds
The system : started=warm start
FastIron Ethernet Switch Administration Guide
53-1003625-01
Compiled on Sep 25 2008 at 04:09:20 labeled as SXR04300b17
(4031365 bytes) from Secondary sxr04300b17.bin
BootROM: Version 04.0.00T3e5 (FEv2)
Serial
#: TExxxxxxxx
Serial
#: CYxxxxxxxxx
P-ASIC
4: type 00D1, rev D2
P-ASIC
5: type 00D1, rev D2
Serial
#: CHxxxxxxxx
P-ASIC 16: type 00D1, rev D2
Serial
#: Invalid
P-ASIC 26: type 01D1, rev 00
P-ASIC 27: type 01D1, rev 00
Software versions installed and running on a device
subrev 00
subrev 00
subrev 00
subrev 00
subrev 00
reloaded=by "reload"