Viewing configuration information
*** NOT FOR PRODUCTION ***
*** AUTO SHUTDOWN IS OFF. PLEASE ACTIVATE WITH auto-shutdown ***
The following hardware details are listed in the output of the show version command:
• Chassis type
• PROM type (if applicable)
• Chassis serial number
• Management and interface module serial numbers and ASIC types
For a description of the software details in the output of the show version command, refer to the
section
Switch Administraiton Guide.
Starting with FastIron 08.0.30, you can view the serial number pluggable modules. If there are no
pluggable modules on the device, the serial number of the fixed modules on the device is displayed.
The following is an example of the show version output on an ICX 7750.
device# show version
Copyright (c) 1996-2014 Brocade Communications Systems, Inc. All rights reserved.
(swz10103b003)
HW: Stackable ICX7750-26Q
Internal USB: Serial #: 40D41E003CF90029
==========================================================================
UNIT 1: SL 1: ICX7750-20QXG 20-port Management Module
==========================================================================
UNIT 1: SL 2: ICX7750-QSFP 6-port QSFP 240G Module
==========================================================================
UNIT 1: SL 3: ICX7750-6Q 6-port QSFP 240G Module
==========================================================================
UNIT 2: SL 1: ICX7750-48XGF 48-port Management Module
==========================================================================
UNIT 2: SL 2: ICX7750-QSFP 6-port QSFP 240G Module
==========================================================================
UNIT 2: SL 3: ICX7750-6Q 6-port QSFP 240G Module
==========================================================================
1500 MHz Power PC processor (version 8023/0022) 88 MHz bus
8192 KB boot flash memory
2048 MB code flash memory
256 MB DRAM
STACKID 1
STACKID 2
The system: started=warm start
Syntax: show version
Viewing configuration information
You can view a variety of configuration details and statistics with the show option. The show option
provides a convenient way to check configuration changes before saving them to flash.
The show options available will vary for Layer 2 Switches and Layer 3 Switches and by configuration
level.
230
Software versions installed and running on a device
UNIT 1: compiled on Dec 22 2014 at 12:35:56 labeled as SWR08030b1
(20833985 bytes) from Secondary SWR08030b1.bin
SW: Version 08.0.30b1T203
UNIT 2: compiled on Dec 22 2014 at 12:35:56 labeled as SWR08030b1
(20833985 bytes) from Secondary SWR08030b1.bin
SW: Version 08.0.30b1T203
Compressed Boot-Monitor Image size = 1835008, Version:10.1.03T205
Vendor: UNIGEN, Total size = 1910 MB
Serial
#:CRK2234J00V
License: ICX7750_L3_SOFT_PACKAGE
P-ASIC
0: type B850, rev 03
Serial
#:PR320400290
Serial
#:CRH2234J00M
License: ICX7750_L3_SOFT_PACKAGE
Serial
#:PR320400289
system uptime is 14 minute(s) 30 second(s)
system uptime is 14 minute(s) 6 second(s)
on page 90 in the FastIron Ethernet
(LID: etmHHIJlFFx)
Chip BCM56850_A2
(LID: etjHHIJlFFo)
reloaded=by "reload"
FastIron Ethernet Switch Administration Guide
53-1003625-01
Need help?
Do you have a question about the FastIron and is the answer not in the manual?