Software Versions Installed And Running On A Device; Determining The Flash Image Version Running On The Device - Brocade Communications Systems FastIron Administration Manual

Ethernet switch
Table of Contents

Advertisement

Software versions installed and running on a device

NOTE
Brocade devices are TFTP clients but not TFTP servers. You must perform the TFTP transaction from
the Brocade device. You cannot "put" a file onto the Brocade device using the interface of your TFTP
server.
NOTE
If you are attempting to transfer a file using TFTP but have received an error message, refer to
Diagnostic error codes and remedies for TFTP transfers

Software versions installed and running on a device

Use the following methods to display the software versions running on the device and the versions
installed in flash memory.

Determining the flash image version running on the device

To determine the flash image version running on a device, enter the show version command at any
level of the CLI. Some examples are shown below.
Compact devices
To determine the flash image version running on a Compact device, enter the show version
command at any level of the CLI. The following shows an example output.
device#show version
Copyright (c) 1996-2012 Brocade Communications Systems, Inc. All rights reserved.
Boot-Monitor Image size = 774980, Version:07.4.00T310 (kxz07400)
HW: Stackable ICX6450-24
==========================================================================
UNIT 1: SL 1: ICX6450-24 24-port Management Module
==========================================================================
UNIT 1: SL 2: ICX6450-SFP-Plus 4port 40G Module
==========================================================================
800 MHz ARM processor ARMv5TE, 400 MHz bus
65536 KB flash memory
512 MB DRAM
STACKID 1
The system : started=warm start
The version information is shown in bold type in this example:
• "03.0.00T53" indicates the flash code version number. The "T53" is used by Brocade for record
keeping.
• "labeled as FER03000" indicates the flash code image label. The label indicates the image type and
version and is especially useful if you change the image file name.
• "Primary fer03000.bin" indicates the flash code image file name that was loaded.
90
UNIT 1: compiled on Mar
(10360844 bytes) from Primary ICX64S07400.bin
SW: Version 07.4.00T311
Serial
#: BZSxxxxxxxx
License: BASE_SOFT_PACKAGE
P-ENGINE
0: type DEF0, rev 01
system uptime is 3 minutes 39 seconds
on page 110.
2 2012 at 12:38:17 labeled as ICX64S07400
(LID: dbuFJJHiFFi)
reloaded=by "reload"
FastIron Ethernet Switch Administration Guide
53-1003625-01

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FastIron and is the answer not in the manual?

Table of Contents

Save PDF