• System-max configuration changes require a system reload. System-max configuration changes do
not take effect by the hitless upgrade. Even if a system-max parameter is changed and saved in the
startup configuration, the FastIron switch will revert to the default system-max value upon a hitless
software upgrade. The new system-max value will only take effect after a regular system reload.
• Other commands requiring a software reload, such as CAM mode changes, also do not take effect
upon hitless upgrade and require a system reload before being placed in effect.
Hitless OS upgrade configuration steps
The following is a summary of the configuration steps for a hitless OS software upgrade.
1. Copy the software image that supports hitless software upgrade from a TFTP server to the FastIron
switch. Refer to
2. Install the software image in flash memory on the active and standby management modules.
3. Enter the hitless-reload command on the active management module. The command triggers the
events described in the section
Loading the software onto the switch
Hitless OS upgrade loads from the primary and secondary images on the FSX 800 and FSX 1600
Management modules. If you will be using the hitless-reload command to perform the hitless upgrade,
you must first copy the software image that supports hitless software upgrade onto the flash memory of
the active and standby management modules. For instructions, refer to the release notes.
Performing a hitless upgrade
After loading the software image onto the flash memory of the active and standby management
modules, you can begin the process of performing a hitless OS upgrade using the hitless-reload
command. For example,
device#hitless-reload primary
Syntax: hitless-reloadprimary | secondary
The primary parameter specifies that the management module will be reloaded with the primary image.
The secondary parameter specifies that the management module will be reloaded with the secondary
image.
NOTE
The hitless-reload command is accepted only when the running configuration and startup configuration
files match. If the configuration file has changed, you must first save the file (write mem ) before
executing a hitless reload. Otherwise, the following message will display on the console.Error: Running
config and start-up config differs. Please reload the system or save the configuration before attempting
hitless reload.

Syslog message for Hitless management events

The following Syslog message is generated as a result of a switchover or hitless OS upgrade.
SWITCHOVER COMPLETED - by admin - Mgmt Module in slot
slotnum
is now Active
FastIron Ethernet Switch Administration Guide
53-1003625-01
Loading the software onto the switch
What happens during a Hitless OS upgrade
Hitless OS upgrade configuration steps
on page 131.