Syntax
sysmon ecc-error -count { threshold events polling-interval | log-backoff value | action { none |
syslog } }
no sysmon fa error-count
Parameters
threshold
events
polling-interval
log-backoff
action
none
syslog
Modes
Global configuration mode.
Usage Guidelines
This command is supported only on FCX and ICX devices.
Examples
The following example configures system monitoring for fabric adaptor errors:
Brocade(config)# sysmon ecc-error threshold 3 7
Brocade(config)# sysmon ecc-error action syslog
Brocade(config)# sysmon ecc-error log-backoff 15
sysmon link-error
Configures how sysmon handles link errors. The no version of this command disables system
monitoring on link errors.
Syntax
sysmon link-error { threshold events polling-interval | log-backoff value | action { none | syslog } }
no sysmon link-error
FastIron Ethernet Switch Administration Guide
53-1003625-01
Defines the threshold for errors. The threshold is defined as N/W, where N is the number of
events, and W is the number of consecutive polling periods. When the threshold is reached,
actions configured for this event type will take place. Note that a threshold of 1/W implies
that there is no threshold, and the action will always be triggered.
Specifies the threshold in terms of the number of events. Valid values are 1 through
10.
Specifies the number of polling windows. The device polls the internal registers at the
interval specified by the sysmon timer value. Valid values 1-32. However, the polling
window number must be equal or greater than the number of events.
If an error condition persists, it will be continuously logged (internally and/or externally to
syslog as defined by the action). The log back-off count skips configured number of logs
before logging again.
Specifies the action to take when error count exceeds the specified threshold and log back-
off values.
The error is logged in the internal sysmon logs. This is the default value.
The error is logged to syslog.
sysmon link-error