sysmon fa error-count
•
sysmon fa link
•
show sysmon counters
•
show sysmon logs
•
show sysmon config
sysmon fa error-count
Configures how sysmon handles fabric adaptor-related errors. The no version of this command disables
system monitoring on fabric adaptors.
Syntax
sysmon fa error-count { threshold events polling-interval | log-backoff value | action { none |
syslog } }
no sysmon fa error-count
Parameters
threshold
events
polling-interval
log-backoff
action
none
syslog
Modes
Global configuration mode.
Usage Guidelines
This command is supported only on FSX devices.
FastIron Ethernet Switch Administration Guide
53-1003625-01
on page 271
on page 272
on page 278
on page 278
on page 282
Defines the threshold for errors. The threshold is defined as N/W, where N is the number of
events, and W is the number of consecutive polling periods. When the threshold is reached,
actions configured for this event type will take place. Note that a threshold of 1/W implies
that there is no threshold, and the action will always be triggered.
Specifies the threshold in terms of the number of events. Valid values are 1 through
10.
Specifies the number of polling windows. The device polls the internal registers at the
interval specified by the sysmon timer value. Valid values 1-32. However, the polling
window number must be equal or greater than the number of events.
If an error condition persists, it will be continuously logged (internally and/or externally to
syslog as defined by the action). The log back-off count skips configured number of logs
before logging again.
Specifies the action to take when a fabric adapter error count exceeds the specified
threshold and log back-off values.
The error is logged in the internal sysmon logs. This is the default value.
The error is logged to syslog.
sysmon fa error-count