7.6 Input settings

7.6.1 No-signal input monitoring

Menu
Top→INPUT SETTING→INPUT VIDEO DETECT
Setting for
Each input (only digital input)
Setting value OFF,2000ms to 15000ms (by 100 ms.) [Default]: 10000ms
If you change the settings of EDID of the MSD or turn off/on the MSD, the source device may not output video
signal.
In this case, the MSD repeatedly requests the source devices to output signal data.
Use this menu to set the monitoring time which is from when a source device stops outputting signal to when
the MSD requests the source device to output video signal.
If you use this input monitoring function and the power-saving function of the PC's monitor simultaneously, the
PC may output video again only after the time set in this menu passes following that the monitor power save
function works. If you enable the monitor power save function, set this menu to "OFF".
If this function works with the Dual monitor function simultaneously, the PC may determine there is no
monitor connection and it may reset the Dual monitor function. In this case, set this menu to "OFF".
Changing EDID
ON
Video signals from
source device
OFF
ON
Hot plug
OFF
[Fig. 7.7] Monitoring absence of input

7.6.2 HDCP input enabled/disabled

Menu
Top→INPUT SETTING→HDCP INPUT ENABLE
Setting for
Each input (only digital input)
Setting value ENABLE [Default], DISABLE
Some source devices check whether the connected device supports HDCP and then determine whether they
encrypt HDCP signal or not. Since the MSD is HDCP compliant, if it is connected to a sink device that is not
HDCP compliant, the sink device may not display video.
You can set whether the MSD encrypts HDCP to the source device. "ENABLE" is set by default, but if you
want to connect the MSD to a sink device that is not HDCP compliant, select "DISABLE" to disable the
encryption of HDCP output from the source device.
Requesting source device to
output video signals
Monitoring time
Changing EDID
Monitoring
ON
Video signals from
source device
OFF
Video output timing of source device
MSD-501/502/701/702 User's Guide
Requesting source device to output video signals
Monitoring
Monitoring
time
time
time
[Fig. 7.8] Repeating reset
41