MSD-501/502/701/702 User's Guide

7.4.11 Test pattern

Menu
Top→OUTPUT TIMING→TEST PATTERN
Setting for
Each output (COMMON TO OUTA AND OUTB)
Setting value [Fig. 7.5]
OFF [Default]
V-COLOR BAR
normal video output
HORIZONTAL
100% WHITE
LAMP
CROSS HATCH OUTPUT FRAME
You can select a test pattern to be output instead of displaying video.
All settings of "7.5 Quality setting" will be invalid while a test pattern is displayed.
For "OUTPUT FRAME": use this pattern if edges are cut off due to enlargement display on the sink device.
Settings of "7.4.6 Display position" and "7.4.7 Display size" in the output side will be adjusted in order to
display the test pattern on full screen.
For test patterns other than "OUTPUT FRAME": video is output on full screen with the resolution set in "7.4.1
Output resolution" and the settings of "7.4.6 Display position", "7.4.7 Display size" and "7.4.8 Masking"
will be invalid.
You can scroll "COLOR BAR","GRAY SCALE","LAMP", and "ZEBRA" by using arrow keys ( , ▲, ▼). The
scroll speed can be set by 3 pixels/a frame up to 30 pixels/ a frame with ▲ and ▼ keys.
You can check the residual image (resolution of moving picture) by displaying "ZEBRA".
38
H-COLOR BAR
50% WHITE
RASTER
RASTER
VERTICAL
STRIPE
[Fig. 7.5] Test pattern
V-GRAY SCALE
H-GRAY SCALE
RED RASTER
GREEN RASTER BLUE RASTER
HORIZONTAL
VERTICAL
ZEBRA
STRIPE
VERTICAL LAMP
HORIZONTAL
ZEBRA