9 Click OK.
The cascade-enabled dial-out link is created and the system automatically dials out to connect the
participant to the linked conference, as well as the destination conference.

Enabling Cascaded Conferences without Password

If a password is assigned to the linked conference, cascaded links will be prompted for a password when
connecting to it (Conference A). Administrators have the option of altering the MCU settings to enable
cascaded links to connect without a password.
To enable cascaded links to connect without a password:
1 In the RealPresence Collaboration Server web client connected to MCU A (where the linked
conference is running), click Setup >System Configuration.
The System Flags dialog box opens.
2 Set the
ENABLE_CASCADED_LINK_TO_JOIN_WITHOUT_PASSWORD
3 Click OK.
For more information, see
Reset the MCU for flag changes to take effect.
Monitoring Star Cascaded Conferences
To monitor both conferences at the same time, two instances of the RealPresence Collaboration Server
Web Clients must be opened (one for each MCU) by entering the IP Address of each MCU. If both
conferences are running on the same MCU, only one RealPresence Collaboration Server Web Client
window is required.
When conferences are cascaded, the Participant List pane of each of the two conferences will display a
linked icon (
); a dial-in linked icon in the destination conference (Conference B) and a dial-out linked icon
in the linked conference (Conference A).