Management Redundancy on RealPresence Collaboration Server (RMX) 1800

On the RealPresence Collaboration Server 1800, for Management Redundancy, the LAN 2 port is
redundant to the LAN 1 port and must have a LAN cable connected.
LAN Redundancy is not supported by Collaboration Server (RMX) 1800-0.
RealPresence Collaboration Server 1800 - LAN 2 connection on Rear Panel
On the RealPresence Collaboration Server 1800, Management Redundancy is implemented using the LAN
1 and LAN 2 ports and is dependent on the settings of the LAN_REDUNDANCY and
MULTIPLE_SERVICES System Flags as summarized in the following table.
RMX 1800 - Management Redundancy - System Flags
Flag / Value
LAN_REDUNDANCY
MULTIPLE_SERVICES = NO
LAN_REDUNDANCY
MULTIPLE_SERVICES = YES
LAN_REDUNDANCY
MULTIPLE_SERVICES = NO
LAN_REDUNDANCY
MULTIPLE_SERVICES = YES
Polycom, Inc.
Port Usage
LAN 1
= NO
Management
= NO
Management
= YES
Management, Media and Signaling.
= YES
These flags cannot be set to YES simultaneously.
IP Network Services
LAN 2
Media and Signaling
Media and Signaling
LAN 2 is redundant to LAN 1