7500-432, -632, and -832
Scanner Manual Registration
Note: All scanner and ADF manual registration alignment verifications must be done in standard user mode,
not in configuration or diagnostic mode.
Note: You should verify the printer registration alignment before conducting the manual scanner registration
process. For information on the printer registration process, see
You can adjust the device's scanner and ADF registration through a manual process. Perform this operation
when any of the following events occur:
•
The scanner controller card has been replaced. (Refer to the settings label on the rear of the machine.)
•
The flatbed scanner unit assembly has been replaced.
•
The ADF unit assembly has been replaced.
•
The CCD card/lens assembly has been replaced.
•
Symptoms indicate that the scanner is not properly aligned.
Printing the registration test original page
Perform this process to acquire the registration test original page. This is the page required to align the
registration for the flatbed scanner and ADF side 1 and ADF side 2.
1.
Ensure the printer media tray registration in all trays is set correctly.
2.
Enter configuration menu. Go to
3.
Touch REGISTRATION.
4.
Touch Quick Test. At this time the registration test original page will be printed.
The registration test original page should appear as shown in graphic below:
3-26
MFP Service Manual
"REGISTRATION" on page
"Configuration Menu" on page
3-36.
3-33.
Previous
Next
Go Back