Lubrication Specifications; Scheduled Maintenance - Lexmark X862de Service Manual

Hide thumbs Also See for X862de:
Table of Contents

Advertisement

7500-432, -632, and -832
LEXMARK X860de, X862de,
X864de
Duplex Transport Roll Middle
EXIT 2
Exit 2 Transport Roll
Exit 2 Media Exit Roll
FINISHER (if equipped)
Bridge Unit Transport Belts
Main Paddles (3)
Sub Paddles (2)
Clamp Paddles (3)
Punch Waste Box
Stapler Cartridge
FLATBED SCANNER
Mirrors (3)
Lens
Small Platen Glass
Large Platen Glass
LEXMARK X860de, X862de,
X864de
ADF
Feed Pick Roll Assembly
Separation Roll Guide Assembly Inspect
ADF Registration Roll Assembly Inspect
ADF Feed-Out Roll Assembly
ADF Exit Roll Assembly
ADF Transport Roll Assembly

Lubrication specifications

Lubricate only when parts are replaced or as needed, not on a scheduled basis. Use of lubricants other than
those specified can cause premature failure. Some unauthorized lubricants may chemically attack
polycarbonate parts. Use IBM no. 10 oil, P/N 1280443 (Approved equivalents: Mobil DTE27, Shell Tellus 100,
Fuchs Renolin MR30), IBM no. 23 grease (Approved equivalent Shell Darina 1), and grease, P/N 99A0394 to
lubricate appropriate areas.

Scheduled maintenance

The LCD displays 80 scheduled maintenance at each 300K page count interval. It is necessary to replace the
fuser assembly, transfer roller, and feed, pick and separation rollers at this interval to maintain the print quality
and reliability of the printer. The parts are available as a maintenance kit with the following part numbers:
40X0394—Maintenance Kit, 110 V
40X0398—Maintenance Kit, 220 V
40X2377—Maintenance Kit, 100 V
The ADF requires scheduled maintenance at each 150K page count interval. It is necessary to replace the feed/
pick roll assembly and the separation guide assembly at this interval to maintain ADF media feed reliability. The
parts are available as a maintenance kit with the following part number:
40X2734—Maintenance Kit, ADF
6-2
MFP Service Manual
EVERY SERVICE CALL
Inspect
Inspect
Inspect
Clean
Clean
EVERY SERVICE CALL
Inspect
Inspect
Inspect
Inspect
EVERY 300K
NOTE:
Clean
Water or alcohol
Clean
Water or alcohol
Clean
Water or alcohol
Clean
Water or alcohol
Inspect
Inspect
Inspect
Clean
Inspect
Check for correct operation
Clean
Glass cleaner
Clean
Glass cleaner
Clean
Glass cleaner
Clean
Glass cleaner
EVERY 150K
NOTE:
Replace
Replace
Clean
Water or alcohol
Clean
Water or alcohol
Clean
Water or alcohol
Clean
Water or alcohol
Previous
Next
Go Back

Advertisement

Table of Contents
loading

This manual is also suitable for:

X864deX860de7500-4327500-6327500-832

Table of Contents