Scanner Tests; Asic Test; Feed Test (Scanner Tests); Scanner Manual Registration - Lexmark X95x series Service Manual

Hide thumbs Also See for X95x series:
Table of Contents

Advertisement

The Menu Settings Page report generates a list of the Diagnostic Menu settings and each setting's current
value.

SCANNER TESTS

ASIC Test

This setting initiates a scan of the scanner ASIC's memory.

Feed Test (SCANNER TESTS)

This setting enables a user to execute a continuous feed test from either the ADF or the flatbed.
To perform the Feed Test:
Touch SCANNER TESTS from the Diagnostics Menu.
1.
Touch Feed Test.
2.
You are prompted to select a paper size for the ADF. For flatbed scans, the full length of the flatbed is traversed.
The device decides whether to run the flatbed or the ADF according to the following flowchart:
During the test, Running... Flatbed:xxxxx ADF:xxxxx appears on the LCD. The Flatbed number increases
each time the scanner performs a flatbed scan, and the ADF number increases each time the scanner performs
an ADF scan.
Press Stop to end this test.
If an error occurs (such as a scanner jam), Feed Test Failed Flatbed:xxxxx ADF:xxxxx appears on the LCD.
To clear the message, press Stop.

Scanner Manual Registration

This setting is for making adjustments to control the scanner's alignment.
To manually register the ADF:
From the Diagnostics Menu, navigate to Scanner Manual Registration > Print Quick Test to print a
1.
Quick Test page.
To view the ADF's current registration:
2.
Place the Quick Test page in the ADF with the image facing up, and touch Copy Quick Test to view
the frontside registration.
Place the Quick Test page in the ADF with the image facing down, and touch Copy Quick Test to
view the backside registration.
Adjust the ADF's registration by changing the settings below:
3.
Note: Lead refers to the edge of the paper parallel to the scanner carriage. Side refers to the edge of the
paper perpendicular to the scanner carriage.
Paper
No
in
ADF?
Yes
Scan all pages
Scan the full
from the ADF,
length of the
assuring selected
flatbed.
paper size.
7558-xxx
Previous
Go Back
Diagnostic aids
3-27
Next