8.17.2 Replacing the planetary gear

Requirements:
· 4 mm Allen key
· 5 mm Allen key
· 13 mm jaw spanner
· Size 2 Phillips recessed head spanner
· Snap ring pliers
Dismantling the planetary gear:
·
Loosen and remove the four Allen screws on the plastic cover (1) using a 4 mm Allen key.
·
Remove the plastic cover.
·
Loosen and remove the Phillips screw (3).
·
Remove the reflector (4).
·
Remove the snap ring under the reflector (not in the picture).
·
Undo the two Allen screws (6) with a 5 mm Allen key.
·
Remove the Allen screws (6) incl. the washers and the stick holder (5) if necessary.
·
When replacing both planetary gears or dismantling the entire back section, also now loosen
and remove the Allen screws (6) incl. the washers on the other side of the mobility aid.
·
Undo the two Allen screws (2) with a 5 mm Allen key. You will need an additional 13 mm jaw
spanner for the opposite nut on the right side of the mobility aid.
·
Remove the Allen screws (2) incl. the washers and the nut if necessary.
·
Pull the planetary gear from the axle.
·
Replace the planetary gear.