Remove the securing clip (4).
·
Remove the spacer (3).
·
Carefully remove the bolts (1) which connect the shock absorber (2) to the swing arm (5).
·
Loosen the four Allen screws (6) with a 6 mm Allen key and a 13 socket spanner.
·
Remove the screws together with the washers.
·
Pull the motor/transmission unit (8) out of the mounting (7) in a forward direction. In doing so,
please observe the high weight of the unit.