Loosen the fixation screw (5) with a 4 mm Allen key.
·
Flip the cover (6) down.
·
Loosen and remove the both fixation screws with a Phillips screwdriver size 2 and an 8 mm
socket spanner.
·
Remove the relais (8)(9) including the mountings (3)(10).
·
Loosen the five Allen screws (11) with an 3 mm Allen key and remove the screws including the
washers and nuts form the mountings.
·
Replace the relais.
Note
When disassembling, take care of small parts such as screws and washers. Put all small parts
down so that they can be reassembled in the right sequence.
Refitting the relais:
·
Refit the parts in reverse order.
·
To conclude, check all the mobility aid functions.