- STORM
PROBLEM
Transmission
losing oil
Irregular
running
Parts lost
Batteries not
being charged
Short
charging
period
Mobility aid
runs too
slowly
4 ®
Series
OTHER
POSSIBLE
SYMPTOMS
CAUSE
None
Sealing ring on
drive shaft
defective
Drive shaft
None
movable or bent
None
Parts lost
None
Fuse burnt out,
cable defective
Batteries
defective
LEDs blinking
Charging unit
on charging
defective
unit
None
One of the
batteries could
be defective
None
Remote
defective
Batteries
defective
SOLUTION
Documentation
Replace
See chapter 8.11.1.
transmission if
sealing ring
defective.
Check carbon
See chapters 8.11.1 and
brushes for oil
8.11.4
wetting, replace
motor if brushes
wet
Check drive shaft,
See chapter 8.11.1.
replace
transmission if
defective.
Reattach parts
once found.
Check cabling and
See chapters 8.6 and 8.5
replace fuse
Replace batteries
See chapter 8.4.2.
Replace charging
See charging unit
unit
operating manual
Replace batteries
See chapter 8.4.2.
Replace remote
See chapter 8.2.1.
Replace batteries
See chapter 8.4.2.