Invacare Storm4 Series Service Manual page 31

Hide thumbs Also See for Storm4 Series:
Table of Contents

Advertisement

®
Invacare
- STORM
PROBLEM
Motors stop
and start
again
Motor runs
but loses
power
Motors stop
and do not
start again
Motors lose
power
during
journey
Motor
judders or
runs
irregularly,
or only one
motor runs
4 ®
Series
OTHER
POSSIBLE
SYMPTOMS
CAUSE
None
Voltage decline
None
High motor load
allows the power
module to lower
the voltage.
None
High motor load
allows the power
module to lower
the voltage.
None
Fuse burnt out
None
Motor defective
None
Power module
defective
None
Bad connections Switch mobility aid
None
Carbon brushes
worn
Bearing
defective
Collector
defective
SOLUTION
Documentation
Stop journey and
allow electronics to
cool down.
Stop journey and
allow electronics to
cool down.
Leave mobility aid
switched on and
let the power
module operate.
Charge batteries
overnight with
mobility aid
switched on.
Check cabling and
See chapters 8.6 and 8.5
replace fuse
Check carbon
See chapter 8.11.4.
brushes and
replace if
necessary
Measure internal
See chapters 7.1 and
resistance of
8.11.1 or 8.12.1.
motor, replace
motor if defective.
Replace power
See chapter 8.2.2. or
module
8.2.3
See chapter 8.6.
off, wait 10
seconds, switch
mobility aid on
again. Check all
cabling.
Check carbon
See chapter 8.11.4.
brushes and
replace if
necessary
Replacing the
See chapter 8.11.1. or
motor
8.12.1.
Measure internal
See chapters 7.1 and
resistance of
8.11.1 or 8.12.1.
motor, replace
motor if defective.
SERVICE MANUAL