Note
The countersunk screw (2) material quality must be at least 8.8.
If spacers have been fitted, the screws length should be completed as follows:
A = thickness of safety plate and spacers
Screw length = A + 6mm
Fitting the DAHL Docking Station:
·
Lay the mobility device on its side and secure it against tipping over. Use proper lifting
techniques.
·
Undo and remove the five bolts (1) including the washers on the underside of the chassis.
·
Calculate the required screw length in accordance with the above formula.
·
Select five M8 Allen key countersunk screws in accordance with DIN 7991 to suit the
calculated length.
·
Fit the spacers (4) and the safety plate (3) over the drillholes.
·
Fit the Allen screws (2) with a high-strength screw blocker system such as Loctite 270.
·
Fit the remaining parts in the reverse order.
·
To conclude, check all fittings for secure connection.