Place the mobility aid on its side and safeguard it against overturning. Use proper lifting
techniques.
·
Loosen and remove the four torx screws (3) on the underside of the chassis (2).
·
Remove the lifting column (1).
Refitting the lifting column:
·
Refit the parts in reverse order.
·
To conclude, check all the mobility aid functions.