LH
HEATING & AIR CONDITIONING (Continued)
A/C APPLICATION TABLE-MTC
Item
Description
Vehicle
LH - Intrepid,
Concorde,
300M, LHS
System
R134a
w/expansion
valve
Compressor
Nippondenso
10PA17
Freeze–up
2-wire
Control
evaporator
temp sensor
Low psi Control
A/C pressure
transducer, line
mounted
High psi Control
Forced Recirc
System forced
Mode
into Recirc at
high pressures
Control Head
Manual type
TORQUE SPECIFICATIONS
DESCRIPTION
A/C COMPRESSOR SHAFT BOLT
A/C COMPRESOR LINE MANIFOLD FASTENERS
A/C COMPRESSOR TO ENGINE BLOCK BOLTS
A/C CONDENSER TO REFRIG. LINES
A/C EXPANSION VALVE TO EVAPORATOR
A/C EXPANSION VALVE TO LINES
A/C PRESSURE TRANSDUCER
BLOWER MOTOR SCREWS
DOOR ACTUATOR SCREWS
HVAC HOUSING SCREWS
HVAC HOUSING TO DASH PANEL NUTS
(ENGINE COMP. SIDE)
HVAC HOUSING TO DASH PANEL NUTS/
SCREWS (PASSENGER COMP. SIDE)
RECEIVER / DRIER TO LINE FASTENERS
Item
Mode Door
Notes
manual A/C
Blend Door
control
Recirculation
Door
Blower Motor
ND-8 PAG oil
Cooling Fans
BCM controlled,
clutch OFF <
Clutch
33° F, resets >
Control
37° F
Draw
Opens < 29.4
psi PCM input
Gap
Opens > 431.0
DRB III
psi PCM input
Reads
BCM steps
HVAC into
recirc at 375
Actuators
psi, steps out at
325 psi
BCM
diagnostics
TORQUE SPECIFICATIONS
17.5 ± 2
HEATING & AIR CONDITIONING 24 - 7
Description
Electric
actuator
Electric
actuator
Electric
actuator
Hardwired to
control head
2 fans, low
speed and high
speed
Relay
2.2 amps @ 12
V ±0.5V
0.014 - 0.026
TPS, RPM, A/C
switch test
Mode doors,
clutch and fan
relays
N·m
Ft. Lbs.
13 ±2
23
17
28
21
23
17
23
17
23
17
6
4
2.2
1.7
2.2
1.7
2.2
1.7
7
5
4.5
3
13.6
10
Notes
BCM controlled
actuators use a
common ground
Resistor block
PCM controlled
via 2 relays
PCM
In. Lbs.
155 ± 20
204
252
204
204
204
50
20
20
20
60
40
120