P003 Maximum Process Speed
Determines level change reaction.
Primary Index
Values
Alters
Related
Use a setting just fast enough to keep up with your process. Slower settings provide
higher accuracy. Faster settings allow for more level fluctuations.
P004 Transducer
Specifies the Siemens Milltronics transducer connected to the unit.
Primary Index
Values
7ML19985FC03
Transducer
1
Slow (0.1 m/min)
2
*
Medium (1 m/min)
3
Fast (10 m/min)
•
P070 Failsafe Timer
•
P700 Max Fill Rate
•
P701 Max Empty Rate
•
P702 Filling Indicator
•
P703 Emptying Indicator
•
P704 Rate Filter
•
P710 Fuzz Filter
•
P713 Echo Lock Window
•
P727 Scan Delay
•
P841 Long Shot Number
•
Failsafe (P070 to P072)
•
P121 Pump by Rate
•
Rate (P700 to P708)
•
Measurement Verification (P710 to P713)
•
Transducer Scanning (P726 to P729)
•
P905 Transmit Pulse
Single Point Model
Global
0
*
No transducer attached (preset for Dual Point)
1
ST-25
2
ST-50
100
STH
101
XCT-8
102 *
XPS-10 (preset for Single Point Model)
103
XCT-12
104
XPS-15
112
XRS-5
250
mA input [6 relay model]
HydroRanger 200 – INSTRUCTION MANUAL
Dual Point Model
Transducer
(chart cont' d next page)
Page 119