Switchport Autostate Exclude - Dell Catalyst 3130 Command Reference Manual

Blade switch
Table of Contents

Advertisement

Chapter 2 Cisco Catalyst Blade Switch 3120 for HP Cisco IOS Commands

switchport autostate exclude

Use the switchport autostate exclude interface configuration command to exclude an interface from
the VLAN interface (switch virtual interface) line state up or down calculation. Use the no form of this
command to return to the default setting.
Syntax Description
This command has no arguments or keywords.
Defaults
All ports in the VLAN are included in the VLAN interface link-up calculation.
Command Modes
Interface configuration
Command History
Release
12.2(46)SE
Usage Guidelines
Enter the switchport autostate exclude command on a Layer 2 access or trunk port belonging to an SVI.
A VLAN interface (SVI) is up if ports are forwarding traffic in the associated VLAN. When all ports on
a VLAN are down or blocking, the SVI line state is down. For the SVI to be up, at least one port in the
VLAN must be up and forwarding. You can use the switchport autostate exclude command to exclude
a port from the SVI interface up-or-down calculation. For example, you might exclude a monitoring port
from the calculations so that the VLAN is not considered up when only the monitoring port is active.
When you enter the switchport autostate exclude command on a port, the command applies to all
VLANs that are enabled on the port.
You can verify the autostate mode of an interface by entering the show interface interface-id
switchport privileged EXEC command. If the mode has not been set, the autostate mode does not
appear.
Examples
This example shows how to configure autostate exclude on an interface and to verify the configuration:
Switch(config)#interface gigabitethernet 1/0/1
Switch(config-if)#switchport autostate exclude
Switch(config-if)#end
Switch#show interface gigabitethernet1/0/1 switchport
Name: Gi1/0/1
Switchport: Enabled
Administrative Mode: dynamic auto
Operational Mode: down
Administrative Trunking Encapsulation: negotiate
Negotiation of Trunking: On
Access Mode VLAN: 1 (default)
Trunking Native Mode VLAN: 1 (default)
OL-12248-03
switchport autostate exclude
no switchport autostate exclude
Modification
This command was introduced.
Cisco Catalyst Blade Switch 3120 for HP Command Reference
switchport autostate exclude
2-773

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 3032

Table of Contents