v Power Control Network Utilities Menu
This menu allows the user to do a lamp test on the operator panels and display, or
change the I/O type.

POWER CONTROL NETWORK UTILITIES MENU

1. Lamp Test for all Operator Panels
2. Display I/O Type
3. Change I/O Type
98. Return to Previous Menu
1>
– Lamp Test for all Operator Panels
Selecting this option tests the operator panel indicators as follows:
Operator Panel Location
Primary I/O drawer
Secondary I/O drawers
– Display I/O Type
This option displays the I/O type and other data, on the operator panels of the
secondary I/O drawers (blinks in one-second intervals). The I/O type is always
shown as two digits in the upper-right corner of the display. All secondary I/O
types are 84. Nothing displays on the primary I/O drawer operator panel. After
20-30 seconds, the Power Control Network Utilities Menu redisplays on the
console.
– Change I/O Type
Use this option to change the I/O type of the primary I/O drawer or secondary I/O
drawer after a service action or configuration change if the I/O type is incorrect. If
this option is chosen, you are asked to make two entries.
1. For the I/O drawer address (drawer number), type:
- 1 for primary I/O drawer.
- 2 for the secondary I/O drawer.
2. For the I/O type, type:
- 85 for the primary I/O drawer.
- 84 for the secondary I/O drawer.
If you enter an invalid value, a failure message displays on the console. The
Power Control Network Utilities Menu then redisplays on the console.
Lamp Test Results
Indicators blink on and off for approximately 30 seconds.
Indicators come on and stay on for approximately 30 seconds.
Chapter 7. Using the Service Processor