Table 6. Service Processor Error Codes. (continued)
328
Service Guide
Error Code Description
4B26 303A Processor system and scan interface
basic assurance tests detected 1GB
DIMM fault
4B26 51AA Processor system and scan interface
basic assurance tests detected 645W
AC power supply fault
4B26 51AB Processor system and scan interface
basic assurance tests detected 645W
DC power supply fault
4B26 51AC Processor system and scan interface
basic assurance tests detected 595W
AC power supply fault
4B26 51AD Processor system and scan interface
basic assurance tests detected 595W
DC power supply fault
4B27 244C Processor system and 6xx bus
processor runtime diagnostics
detected 1W processor fault
4B27 244D Processor system and 6xx bus
processor runtime diagnostics
detected 2W processor fault
4B27 244E Processor system and 6xx bus
processor runtime diagnostics
detected 4W processor fault
4B27 244F Processor system and 6xx bus
processor runtime diagnostics
detected 1W processor fault
4B27 248B Processor system and 6xx bus
processor runtime diagnostics
detected primary I/O drawer operator
panel
4B27 24A1 Processor system and 6xx bus
processor runtime diagnostics
detected 1W processor fault
Action/
Possible Failing FRU
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
645W AC power supply
Locations:
U1.1-V1
U1.1-V2
645W DC power supply
Locations:
U1.1-V1
U1.1-V2
595W AC power supply
Locations:
U0.1-V1
U0.1-V2
U0.2-V1
U0.2-V2
595W DC power supply
Locations:
U0.1-V1
U0.1-V2
U0.2-V1
U0.2-V2
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Operator panel
Location: U0.1-L1
Processor card
Location: U1.1-P1-C1

Advertisement

Table of Contents
loading

Table of Contents